Categories

Contact Us

Shanghai ZhangNan Chemical Co.,Ltd
Add:The Southeast Of Hongyun Road And Thirteen Road Intersection, New District, Wuxi, Jiangsu, China
Linkedin:1012789136@qq.com
Ph:+86-13695532529
E-mail:penn.hu@wxsmqt.com

Acetylene Gas Bottle

Precautions (1) High-pressure gas cylinders must be classified into sub-offices for storage and storage, and should be kept upright when placed upright. The cylinders should be far away from the heat source to avoid exposure and strong vibration. The general laboratory gas cylinders should not...

Send InquiryChat Now

Product Details

Basic parameters

Material:

Steel

Place of Origin

Jiangsu, China

Brand Name

ZNAN

use

Gas packaging

Model Number

Oxygen

Size

10~50L

Cylinders color

 Any

Working Pressure

150~200Bar

Cylinder size

10~50L


24(001).jpg


Precautions 

(1) High-pressure gas cylinders must be classified into sub-offices for storage and storage, and should be kept upright when placed upright. The cylinders should be far away from the heat source to avoid exposure and strong vibration. The general laboratory gas cylinders should not exceed two bottles.

a. On the shoulder of the cylinder, mark the following markings with steel seals. Manufacturing Date Cylinder Model Working Pressure Pressure Test Pressure Air Pressure Test Date and Next Date, Gas Volume, Cylinder Weight.

b. In order to avoid any confusion when using various cylinders, the cylinders are often painted in different colors, and the gas names in the bottles are indicated.

(2) The pressure reducer used on the high-pressure gas cylinder should be classified according to the specific requirements. When installing, the screw should be screwed tightly to prevent leakage; when the pressure reducer and the on-off valve are opened and closed, the action must be slow; , After opening the pressure reducer; run out, turn off the switch valve, put more than gas, and then off the regulator. Must not stress reducer, not the switch valve.

(3) When using high-pressure gas cylinder, the operator should stand in the vertical position with the cylinder interface. Operation is prohibited beat hit, and often check for leaks, pay attention to the pressure gauge readings.

(4) oxygen bottles or hydrogen bottles, etc., should be equipped with special tools, and is strictly prohibited oil contact. Operators should not wear clothing gloves that are stained with various greases or that may cause static electricity to avoid burning or exploding.

(5) Flammable gas and gas cylinder supporting combustion gas, and the distance from the open flame should be greater than 10 meters (indeed hard to reach, you can take measures such as isolation).

(6) cylinders after use, should be required to stay more than 0.05MPa residual pressure. Flammable gas should be left 0.2MPa ~ 0.3MPa (about 2kg / cm2 ~ 3kg / cm2 gauge) H2 should be kept 2MPa, to prevent the danger of re-inflated, not exhausted.

(7) Various cylinders must be technically checked regularly. Gas cylinders filled with general gas shall be inspected once every three years; if serious corrosion or serious damage is found during use, they shall be inspected in advance.


Product Description

Cylinder model

Outer diameter (mm)

Volume (L)

Length (mm)

Weight (kg)

Working pressure

Test pressure

thickness

material

EN178

178

12

830

17.5

150bar(20MPa)

250bar(30MPa)

4

34CrMo4

EN178

178

12

810

17.5

150bar(20MPa)

250bar(30MPa)

4

34CrMo4

Cylinder model

Outer diameter (mm)

Volume (L)

Length (mm)

Weight (kg)

Working pressure

test pressure

thickness

material

EN178

178

5

315

8.8

150bar(15MPa)

250bar(25MPa)

4

30CrMo

8

450

11.2

10

540

12.8

13.4

695

17.5

15

765

16.8

16.8

845

18.2

18.8

935

19.8

EN178

15.7

815

21

138.9bar(2015psi)

208.4bar(3022psi)

10.8

590

16

EN178

13.4

695

15.6

150bar(15MPa)

250bar(25MPa)

34CrMo4

16

810

17.5

16.8

845

18.2

18.8

935

19.8

EN178

10.7

590

13.5

13.4

715

15.6

16

830

17.5

16.8

865

18.1

18.8

950

19.6

20

1005

20.5



FAQ

1. What's your product price?

Because each gas price depends on your quantity and purity requirements, it is difficult to give a fixed price. If you are interested in some gases, please provide your details. I can offer you an offer.

2. What's the min order?

Different products with different MOQ, please do not hesitate to tell us your needs

3. What's your payment term?

50% T/T deposit, 50% T/T against B/L copy or 100% Irrevocable L/C at sight


Description 

The general working pressure of cylinders are around 150 kg / cm2. For example, oxygen cylinder is sky blue and black; nitrogen cylinder is black and yellow; compressed air cylinder is black and white; chlorine cylinder is grass green and white; Hydrogen cylinders are dark green, red; ammonia cylinder is yellow, black; liquefied petroleum gas cylinders gray, red; acetylene cylinders are white, red, etc.

Our Company

Safety Monitoring Center.

Quality control.

Filling workshop

We have accumulated more than 20 million dollars for the safety of investment funds, which we must insist on doing the most important thing.

Our quality control equipment includes Shimadzu mass spectrometer, halo water analyzer and other testing equipment.

We currently produce 2 million bottles of industrial gas, including high purity gas, electronic gas, rare gas.

Air separation plant.

Acetylene plant.

Hydrogen factory.

We have 16 sets of air separation equipment in the country, 30,000 cubic meters / hour of gas capacity.

We can produce an annual output of 1.8 million bottles of acetylene gas.

We manufacture the electronic grade high purity hydrogen 99.9999%.


27(001).jpg


Trading Information

 

Whether to support a price

no

Price setting

Single FOB range price

FOB price

USD:50-150 Piece

MOQ

210 Piece

payment method

L/CD/AD/PT/TWestern UnionMoneyGramOther


USE

1, before use to check the connection site is leaking, can be coated with soap to check, to confirm airtight experiment.

2. After confirming that the pressure reducing valve is in the off state (T adjusting screw is released), open the total cylinder counterclockwise and observe the pressure gauge reading. Then turn counterclockwise a small switch to the left of the pressure reducing valve and slow down clockwise Slowly turn the pressure regulator adjusting screw (T-Shaft) to compress the main spring to open the valve. The pressure on the decompression table at the desired pressure, record the value of the pressure on the decompression table.

3, after use, turn off the cylinder switch clockwise, then loosen the pressure relief valve counterclockwise.

Precautions

1. Indoor must be well ventilated to ensure that the maximum amount of hydrogen in the air does not exceed 1% (volume ratio). The number of indoor ventilation shall not be less than three times per hour, local ventilation hourly ventilation shall not be less than seven times.

2. The distance between the oxygen cylinder and the container and gas cylinder containing flammable, explosive substances and oxidizing gas shall not be less than 8 meters.

3. And open flame or general electrical equipment spacing should not be less than 10 meters.

4. And air conditioning, air compressors and ventilation devices such as suction outlet spacing should not be less than 20 meters.

5. With other flammable gas storage location spacing should not be less than 20 meters.

6. Forbid percussion, collision; Cylinder not close to heat; Summer should prevent exposure.

7. Must use a dedicated oxygen regulator, open the cylinder, the operator should be standing behind the valve port side, the action should be gentle.

8 valves or pressure relief valve leakage, shall not continue to use. When the valve is damaged, it is forbidden to replace the valve with pressure in the bottle.

9. The gas inside the bottle is forbidden to be used up. The residual pressure above 0.5MPa should be reserved.


Hot Tags: acetylene gas bottle, manufacturers, wholesale, buy, price

Previous:Buy Oxy Acetylene Bottles Next:Oxy Acetylene Bottles

Related Products

Inquiry